MODEL PAVH-06V1GMA (R290)/ HEAT PUMP DC Inverter Air to Water
R290 is one of the best refrigerant available for mass production up to now: Negligible Global Warming Potential (GWP) and degradation time is considered in monthes; Zero ozone layer depletion potential (ODP); Permanent green; Less load for the same performance; Low energy consumption and higher efficiency. Thanks to the use of R290, Migloor heatSTAR+ series (R290) is now not only the best solution for new building, but also possible to fit the retrofit market by lifting up maximum heating temperature to 70°C. With good performance in this water temperature rante, air to water heat pump unit is now possible to be used to replace the old gas/oil boiler without changing the existing heating distribution system, even has old radiators inside.
DATOS TÉCNICOS
Model |
|
PAVH-06V1GMA |
PAVH-09V1GMA |
PAVH-12V1GMA |
PAVH-15V4GMA |
|
---|---|---|---|---|---|---|
Power Supply / Refrigerant |
V/Hz/Ph |
220-240/50/1 - R290 |
220-240/50/1 - R290 |
220-240/50/1 - R290 |
380-400/50/3 - R290 |
|
Max. Heating Capacity (1) |
kW |
6,75 |
9,5 |
12,0 |
16,5 |
|
C.O.P (1) |
W/W |
4,45 |
4,55 |
3,92 |
3,98 |
|
Heating Capacity Min./Max.(1) |
kW |
2.2 / 6.75 |
3.1 / 9.5 |
3.8 / 12 |
5.6/16.5 |
|
Heating Power Input Min./Max.(1) |
W |
470 / 1520 |
585/ 2089 |
900 / 3065 |
1120/4170 |
|
C.O.P Min./Max.(1) |
W/W |
4.45 / 5.05 |
4.6 / 5.1 |
3.92/ 4.8 |
3.98/5.05 |
|
Max. Heating Capacity(2) |
kW |
6,5 |
9 |
11 |
15,5 |
|
C.O.P (2) |
W/W |
3,6 |
3,75 |
3,28 |
3,25 |
|
Heating Capacity Min./Max.(2) |
kW |
2.0 /6.5 |
2.7 /9.0 |
3.7/ 11.0 |
5.3/15.5 |
|
Heating power input Min./Max.(2) |
W |
500 /1800 |
725 / 2400 |
1100 / 3350 |
1370/4770 |
|
C.O.P Min./Max.(2) |
W/W |
3.6 / 3.85 |
3.75 / 4.0 |
3.28/3.7 |
3.25/3.85 |
|
Max. Cooling Capacity (3) |
kW |
5,5 |
8 |
10,2 |
13,2 |
|
E.E.R (3) |
W/W |
4,3 |
3,8 |
3,6 |
3,65 |
|
Cooling Capacity Min./Max.(3) |
kW |
2.7 / 5.5 |
2.4 / 8.0 |
5.0/10.2 |
6.9/13.2 |
|
Cooling Power Input Min./Max.(3) |
W |
620 / 1270 |
765 / 2100 |
1400/2840 |
1540/3650 |
|
E.E.R Min./Max.(3) |
W/W |
4.3 / 4.6 |
3.80 / 4.0 |
3.6/3.9 |
3.65/4.4 |
|
Max. Cooling Capacity (4) |
kW |
3,4 |
6 |
7,5 |
10,1 |
|
E.E.R (4) |
W/W |
2,95 |
2,90 |
2,75 |
2,85 |
|
Cooling Capacity Min./Max.(4) |
kW |
1.6 /3.4 |
1.8 /6.0 |
3.6/7.5 |
4.8/10.1 |
|
Cooling Power Input Min./Max.(4) |
W |
560 /1210 |
720 /1945
|
1330/2740 |
1550/3540 |
|
E.E.R Min./Max.(4) |
W/W |
2.8 / 2.95 |
2.9 / 3.05 |
2.75/2.90 |
2.85/3.05 |
|
Workable Ambient Temperature Range |
℃ |
-25~45 |
-25~45 |
-25~45 |
-25~45 |
|
Max. System Water Temperature (Heating / Cooling) |
℃ |
20 / 70 |
20 / 70 |
20 / 70 |
20 / 70 |
|
Min. System Water Temperature (Heating / Cooling) |
℃ |
20 / 7 |
20 / 7 |
20 / 7 |
20 / 7 |
|
Max. Operation High Pressure |
MPa |
3.10 |
3.10 |
3.10 |
3.10 |
|
Max. Operation Low Pressure |
MPa |
0.82 |
0.82 |
0.82 |
0.82 |
|
Compressor |
Type - Quantity/System |
|
Twin Rotary - 1 |
Twin Rotary - 1 |
Twin Rotary - 1 |
Twin Rotary - 1 |
Refrigerant |
Type / Amount |
- / kg |
R290 / 0.6kg |
R290 / 0.7kg |
R290 /0.9kg |
R290 / 1.5kg |
Fan |
Quantity |
|
1 |
1 |
1 |
2 |
Airflow |
m3/h |
3150 |
3150 |
3300 |
6300 |
|
Rated power |
W |
62 |
62 |
62 |
124 |
|
Noise Level (sound power) |
Indoor/Outdoor |
dB(A) |
30/52 |
30/52 |
30/52 |
30/59 |
Water Side Heat Exchanger |
Type |
|
Plate Heat Exchanger |
Plate Heat Exchanger |
Plate Heat Exchanger |
Plate Heat Exchanger |
Water Pressure Drop |
kPa |
23 |
23 |
23 |
23 |
|
Piping Connection |
Inch |
G1" |
G1" |
G1" |
G1-1/4" |
|
Allowable Water Flow |
Min./Rated./Max. |
L/S |
0.21/0.29/0.35 |
0.21/0.29/0.35 |
0.34/0.57/0.68 |
0.56/0.93/1.12 |
Net Dimension(L×D×H) |
Indoor Unit |
mm |
570x550x260 |
570x550x260 |
570x550x260 |
570x550x260 |
Outdoor Unit |
mm |
1165x370x850 |
1165x370x850 |
1165x370x950 |
1085x390x1450 |
|
Net Weight |
Indoor Unit |
Kg |
25 |
25 |
25 |
25 |
Outdoor Unit |
Kg |
90 |
98 |
110 |
145 |
Note: (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃; (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃; (3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB 35℃/WB 24℃; (4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB 35℃/WB 24℃; (5) The specifications are subject to change without prior notice. For actual specifications of unit, please refer to the stickers on the unit.
Main Components
The overall structural designs of our products have been carefully developed to make the installation and service as easy as possible |
|
Outdoor unit structure. 4 screws to open the fan guard to get access to fan system and bottom plate heater. . 2 screws to open the service panel to compressor system. |
Indoor unit structureFront panel swings open like a door, with easy access to the control system. All connections from controller are connected via terminal blocks. This allows the wiring and trouble-shooting work on the unit clear and easy. Swing open the control box like a door, allowing hydraulic system to become fully exposed, which provides sufficient space to work on any component inside the unit. |
CARACTERÍSTICAS PRINCIPALES
|
|
Control System
AMITIME can be controlled directly by following methods • Operation Panel: Installed on the unit, the panel provides two separate operation systems for the user to choose; EcoTouch and EcoPress. • Smart Phone: By using Amitime APP or APK, users can access to the basic settings remotely via iPhone or Andriod smart phones. • Computer: Users via computer can login Amitime web server remotely and change any setting, view historic running status, as well as update the software from anywhere remotely |
Our Wi-Fi Heat Pump Control application allows users control the basic setting of the heat pump: Turn the system on/off. Change the temperature setting. Change the mode |
Computer Control function is only available for the units equipped with EcoTouch control system. Users, via computer can login Amitime web server remotely and change any setting, view historic running status, as well as update the software from anywhere remotely |
rty