MODEL PAVH-12V1FBA (R32 Monoblock)/ HEAT PUMP DC Inverter Air to Water
MODEL | UNIT TYPE | POWER | SIZE |
---|---|---|---|
PAVH-12V1FBA | HeatStar Monoblock | 12kw | 1230*480*1020 |
The M in Unit name is short for Monoblock. As the name suggests, monoblock equipment are packaged equipment, where all components of the entire system is housed within a single piece of equipment. Monoblock equipment must be located outdoors. The advantages of the monoblock systems are: easy installation and no additional refrigerant piping requirement. It can be simply plumbed to your house's heating system using water connections. Migloor also offers a semi monoblock system, where only a small part of the hydrolic circuitry is separated from the main unit and just as full monoblock systems, requires only simple plumbing connections.
TECHNICAL DATA
Model |
|
PAVH-06V1GMA |
PAVH-09V1GMA |
PAVH-12V1GMA |
PAVH-15V4GMA |
|
---|---|---|---|---|---|---|
Power Supply / Refrigerant |
V/Hz/Ph |
220-240/50/1 - R290 |
220-240/50/1 - R290 |
220-240/50/1 - R290 |
380-400/50/3 - R290 |
|
Max. Heating Capacity (1) |
kW |
6,75 |
9,5 |
12,0 |
16,5 |
|
C.O.P (1) |
W/W |
4,45 |
4,55 |
3,92 |
3,98 |
|
Heating Capacity Min./Max.(1) |
kW |
2.2 / 6.75 |
3.1 / 9.5 |
3.8 / 12 |
5.6/16.5 |
|
Heating Power Input Min./Max.(1) |
W |
470 / 1520 |
585/ 2089 |
900 / 3065 |
1120/4170 |
|
C.O.P Min./Max.(1) |
W/W |
4.45 / 5.05 |
4.6 / 5.1 |
3.92/ 4.8 |
3.98/5.05 |
|
Max. Heating Capacity(2) |
kW |
6,5 |
9 |
11 |
15,5 |
|
C.O.P (2) |
W/W |
3,6 |
3,75 |
3,28 |
3,25 |
|
Heating Capacity Min./Max.(2) |
kW |
2.0 /6.5 |
2.7 /9.0 |
3.7/ 11.0 |
5.3/15.5 |
|
Heating power input Min./Max.(2) |
W |
500 /1800 |
725 / 2400 |
1100 / 3350 |
1370/4770 |
|
C.O.P Min./Max.(2) |
W/W |
3.6 / 3.85 |
3.75 / 4.0 |
3.28/3.7 |
3.25/3.85 |
|
Max. Cooling Capacity (3) |
kW |
5,5 |
8 |
10,2 |
13,2 |
|
E.E.R (3) |
W/W |
4,3 |
3,8 |
3,6 |
3,65 |
|
Cooling Capacity Min./Max.(3) |
kW |
2.7 / 5.5 |
2.4 / 8.0 |
5.0/10.2 |
6.9/13.2 |
|
Cooling Power Input Min./Max.(3) |
W |
620 / 1270 |
765 / 2100 |
1400/2840 |
1540/3650 |
|
E.E.R Min./Max.(3) |
W/W |
4.3 / 4.6 |
3.80 / 4.0 |
3.6/3.9 |
3.65/4.4 |
|
Max. Cooling Capacity (4) |
kW |
3,4 |
6 |
7,5 |
10,1 |
|
E.E.R (4) |
W/W |
2,95 |
2,90 |
2,75 |
2,85 |
|
Cooling Capacity Min./Max.(4) |
kW |
1.6 /3.4 |
1.8 /6.0 |
3.6/7.5 |
4.8/10.1 |
|
Cooling Power Input Min./Max.(4) |
W |
560 /1210 |
720 /1945
|
1330/2740 |
1550/3540 |
|
E.E.R Min./Max.(4) |
W/W |
2.8 / 2.95 |
2.9 / 3.05 |
2.75/2.90 |
2.85/3.05 |
|
Workable Ambient Temperature Range |
℃ |
-25~45 |
-25~45 |
-25~45 |
-25~45 |
|
Max. System Water Temperature (Heating / Cooling) |
℃ |
20 / 70 |
20 / 70 |
20 / 70 |
20 / 70 |
|
Min. System Water Temperature (Heating / Cooling) |
℃ |
20 / 7 |
20 / 7 |
20 / 7 |
20 / 7 |
|
Max. Operation High Pressure |
MPa |
3.10 |
3.10 |
3.10 |
3.10 |
|
Max. Operation Low Pressure |
MPa |
0.82 |
0.82 |
0.82 |
0.82 |
|
Compressor |
Type - Quantity/System |
|
Twin Rotary - 1 |
Twin Rotary - 1 |
Twin Rotary - 1 |
Twin Rotary - 1 |
Refrigerant |
Type / Amount |
- / kg |
R290 / 0.6kg |
R290 / 0.7kg |
R290 /0.9kg |
R290 / 1.5kg |
Fan |
Quantity |
|
1 |
1 |
1 |
2 |
Airflow |
m3/h |
3150 |
3150 |
3300 |
6300 |
|
Rated power |
W |
62 |
62 |
62 |
124 |
|
Noise Level (sound power) |
Indoor/Outdoor |
dB(A) |
30/52 |
30/52 |
30/52 |
30/59 |
Water Side Heat Exchanger |
Type |
|
Plate Heat Exchanger |
Plate Heat Exchanger |
Plate Heat Exchanger |
Plate Heat Exchanger |
Water Pressure Drop |
kPa |
23 |
23 |
23 |
23 |
|
Piping Connection |
Inch |
G1" |
G1" |
G1" |
G1-1/4" |
|
Allowable Water Flow |
Min./Rated./Max. |
L/S |
0.21/0.29/0.35 |
0.21/0.29/0.35 |
0.34/0.57/0.68 |
0.56/0.93/1.12 |
Net Dimension(L×D×H) |
Indoor Unit |
mm |
570x550x260 |
570x550x260 |
570x550x260 |
570x550x260 |
Outdoor Unit |
mm |
1165x370x850 |
1165x370x850 |
1165x370x950 |
1085x390x1450 |
|
Net Weight |
Indoor Unit |
Kg |
25 |
25 |
25 |
25 |
Outdoor Unit |
Kg |
90 |
98 |
110 |
145 |
Note: (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃; (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃; (3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB 35℃/WB 24℃; (4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB 35℃/WB 24℃; (5) The specifications are subject to change without prior notice. For actual specifications of unit, please refer to the stickers on the unit.
Main Components
The overall structural designs of our products have been carefully developed to make the installation and service as easy as possible |
|
Outdoor unit structure. 4 screws to open the fan guard to get access to fan system and bottom plate heater. . 2 screws to open the service panel to compressor system. |
Indoor unit structureFront panel swings open like a door, with easy access to the control system. All connections from controller are connected via terminal blocks. This allows the wiring and trouble-shooting work on the unit clear and easy. Swing open the control box like a door, allowing hydraulic system to become fully exposed, which provides sufficient space to work on any component inside the unit. |
MAIN CHARACTERISTICS
|
|
Control System
AMITIME can be controlled directly by following methods • Operation Panel: Installed on the unit, the panel provides two separate operation systems for the user to choose; EcoTouch and EcoPress. • Smart Phone: By using Amitime APP or APK, users can access to the basic settings remotely via iPhone or Andriod smart phones. • Computer: Users via computer can login Amitime web server remotely and change any setting, view historic running status, as well as update the software from anywhere remotely |
Our Wi-Fi Heat Pump Control application allows users control the basic setting of the heat pump: Turn the system on/off. Change the temperature setting. Change the mode |
Computer Control function is only available for the units equipped with EcoTouch control system. Users, via computer can login Amitime web server remotely and change any setting, view historic running status, as well as update the software from anywhere remotely |
rty
ewr