MODEL PAVH-19V4FBA (R32 SemiMonoblock)/ HEAT PUMP DC Inverter Air to Water

€10,636.00
MODEL UNIT TYPE POWER SIZE
PAVH-19V4FBA HeatStar Monoblock 19kw 1150*480*1610

The M in Unit name is short for Monoblock. As the name suggests, monoblock equipment are packaged equipment, where all components of the entire system is housed within a single piece of equipment. Monoblock equipment must be located outdoors. The advantages of the monoblock systems are: easy installation and no additional refrigerant piping requirement. It can be simply plumbed to your house's heating system using water connections. Migloor also offers a semi monoblock system, where only a small part of the hydrolic circuitry is separated from the main unit and just as full monoblock systems, requires only simple plumbing connections.

MODEL

€10,636.00

TECHNICAL DATA

Model
 
PAVH-06V1GMA
PAVH-09V1GMA
PAVH-12V1GMA
PAVH-15V4GMA
Power Supply / Refrigerant
V/Hz/Ph
220-240/50/1 - R290
220-240/50/1 - R290
220-240/50/1 - R290
380-400/50/3 - R290
Max. Heating Capacity (1)
kW
6,75
9,5
12,0
16,5
C.O.P (1)
W/W
4,45
4,55
3,92
3,98
Heating Capacity Min./Max.(1)
kW
2.2 / 6.75
3.1 / 9.5
3.8 / 12
5.6/16.5
Heating Power Input Min./Max.(1)
W
470 / 1520
585/ 2089
900 / 3065
1120/4170
C.O.P Min./Max.(1)
W/W
4.45 / 5.05
4.6 / 5.1
3.92/ 4.8
3.98/5.05
Max. Heating Capacity(2)
kW
6,5
9
11
15,5
C.O.P (2)
W/W
3,6
3,75
3,28
3,25
Heating Capacity Min./Max.(2)
kW
2.0 /6.5
2.7 /9.0
3.7/ 11.0
5.3/15.5
Heating power input Min./Max.(2)
W
500 /1800
725 / 2400
1100 / 3350
1370/4770
C.O.P Min./Max.(2)
W/W
3.6 / 3.85
3.75 / 4.0
3.28/3.7
3.25/3.85
Max. Cooling Capacity (3)
kW
5,5
8
10,2
13,2
E.E.R (3)
W/W
4,3
3,8
3,6
3,65
Cooling Capacity Min./Max.(3)
kW
2.7 / 5.5
2.4 / 8.0
5.0/10.2
6.9/13.2
Cooling Power Input Min./Max.(3)
W
620 / 1270
765 / 2100
1400/2840
1540/3650
E.E.R Min./Max.(3)
W/W
4.3 / 4.6
3.80 / 4.0
3.6/3.9
3.65/4.4
Max. Cooling Capacity (4)
kW
3,4
6
7,5
10,1
E.E.R (4)
W/W
2,95
2,90
2,75
2,85
Cooling Capacity Min./Max.(4)
kW
1.6 /3.4
1.8 /6.0
3.6/7.5
4.8/10.1
Cooling Power Input Min./Max.(4)
W
560 /1210
720 /1945
1330/2740
1550/3540
E.E.R Min./Max.(4)
W/W
2.8 / 2.95
2.9 / 3.05
2.75/2.90
2.85/3.05
Workable Ambient Temperature Range
-25~45
-25~45
-25~45
-25~45
Max. System Water Temperature (Heating / Cooling)
20 / 70
20 / 70
20 / 70
20 / 70
Min. System Water Temperature (Heating / Cooling)
20 / 7
20 / 7
20 / 7
20 / 7
Max. Operation High Pressure
MPa
3.10
3.10
3.10
3.10
Max. Operation Low Pressure
MPa
0.82
0.82
0.82
0.82
Compressor
Type - Quantity/System
 
Twin Rotary - 1
Twin Rotary - 1
Twin Rotary - 1
Twin Rotary - 1
Refrigerant
Type / Amount
- / kg
R290 / 0.6kg
R290 / 0.7kg
R290 /0.9kg
R290 / 1.5kg
Fan
Quantity
 
1
1
1
2
Airflow
m3/h
3150
3150
3300
6300
Rated power
W
62
62
62
124
Noise Level (sound power)
Indoor/Outdoor
dB(A)
30/52
30/52
 30/52 
30/59
Water Side Heat Exchanger
Type
 
Plate Heat Exchanger
Plate Heat Exchanger
Plate Heat Exchanger
Plate Heat Exchanger
Water Pressure Drop
kPa
23
23
23
23
Piping Connection
Inch
G1"
G1"
G1"
G1-1/4"
Allowable Water Flow
Min./Rated./Max.
L/S
0.21/0.29/0.35
0.21/0.29/0.35
0.34/0.57/0.68
0.56/0.93/1.12
Net Dimension(L×D×H)
Indoor Unit
mm
570x550x260
570x550x260
570x550x260
570x550x260
Outdoor Unit
mm
1165x370x850
1165x370x850
1165x370x950
1085x390x1450
Net Weight
Indoor Unit
Kg
25
25
25
25
Outdoor Unit
Kg
90
98
110
145

Note: (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃; (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃; (3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB 35℃/WB 24℃; (4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB 35℃/WB 24℃; (5) The specifications are subject to change without prior notice. For actual specifications of unit, please refer to the stickers on the unit.

Main Components

The overall structural designs of our products have been carefully developed to make the installation and service as easy as possible

componentes1.png 

Outdoor unit structure

. 4 screws to open the fan guard to get access to fan system and bottom plate heater.

. 2 screws to open the service panel to compressor system.

Indoor unit structure

Front panel swings open like a door, with easy access to the control system. All connections from controller are connected via terminal blocks. This allows the wiring and trouble-shooting work on the unit clear and easy. Swing open the control box like a door, allowing hydraulic system to become fully exposed, which provides sufficient space to work on any component inside the unit.

MAIN CHARACTERISTICS

  • High energy efficiency and stable performance with full inverter technology, it reaches A+++ energy level and COP is up to 5.
  • Monoblock design for easy installation
  • Low noise solution with EC fan motor and improved air duct system, as low as 52dB(A)
  • Supply high water temperature up to 70℃. Work down to -25℃


Control System

AMITIME can be controlled directly by following methods

• Operation Panel: Installed on the unit, the panel provides two separate operation systems for the user to choose; EcoTouch and EcoPress.

• Smart Phone: By using Amitime APP or APK, users can access to the basic settings remotely via iPhone or Andriod smart phones.

• Computer: Users via computer can login Amitime web server remotely and change any setting, view historic running status, as well as update the software from anywhere remotely

Our Wi-Fi Heat Pump Control application allows users control the basic setting of the heat pump: Turn the system on/off. Change the temperature setting. Change the mode    

Computer Control function is only available for the units equipped with EcoTouch control system. Users, via computer can login Amitime web server remotely and change any setting, view historic running status, as well as update the software from anywhere remotely

You might also like

Get ahead of the solar energy trends with our new selection

Boxed:

Sticky Add To Cart

Font: